Komatsu — E-24 MALFUNCTION OF WIPERS

TROUBLESHOOTING E-24 D85EX-15 20-645 (1) Trouble (6) • The right door wiper does not operate intermittently. Related information • Carry out the following troubleshooting when the ordinary operation is normal. • When carrying out the troubleshooting, turn the wiper switch and intermittent switch ON. • Stop about 5 seconds after the wiper goes and returns once. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective intermittent switch • If the ordinary operation is normal and the other wiper do not operate intermittently either, the intermittent switch is probably defective.

aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. CN11 (female) Position of switch Voltage Between (1) – (2) ON Max. 1z OFF Min. 1 Mz 2 Defective right door wiper intermittent selector relay • If the trouble is repaired by replacing the relay with relay CN27, CN29, or CN33, the relay is defective. aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Between CN31 (1) – ground Voltage 20 – 30V Between CN31 (5) – ground Voltage 20 – 30V 3 Defective right door wiper intermittent relay • If the trouble is repaired by replacing the relay with relay CN26, CN28, or CN32, the relay is defective.

aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Between CN30 (2) – ground Voltage 20 – 30V 4 Disconnection or short cir- cuit with chassis ground in wiring harness (Disconnec- tion in wiring or defective contact in connector or con- tact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CN11 (female) (2) – CN31 (female) (1) Resistance Max. 1z Contact of wiring harness between CN11 (fe- male) (2) – CN31 (female) (1) with ground Resistance Min. 1 Mz Wiring harness between CN31 (female) (5) – CN30 (female) (2) Resistance Max.

1z Contact of wiring harness between CN31 (fe- male) (5) – CN30 (female) (2) with ground Resistance Min. 1 Mz Wiring harness between CN31 (female) (2) – ground Resistance Max. 1z