Komatsu — E-26 THE AIR CONDITIONER DOES NOT OPERATE

TROUBLESHOOTING E-26 D85EX-15 20-659 (1) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 10 Disconnection of wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. Wiring harness between CN-P (female) (7B) and CN-R5 (female) (7A) Resistance Max. 1z Wiring harness between CN-P (female) (6B) and AC1 (female) (6A) Resistance Max. 1z 11 Defective control panel When Causes 1 to 10 are not applicable, the control panel is supposed to be defective.