Komatsu — INSTALLATION

DISASSEMBLY AND ASSEMBLY NOZZLE TIP INSTALLATION 5. Install nozzle assembly (3) and tighten retaining nut (2) with the fingers. 1. Grip tool A5 with vise [1]. a Do not hold the injector directly with the vise. 6. Set 19-mm deep socket [2] to a torque wrench and tighten the retaining nut according to the fol- lowing procedure. a Apply rust-preventive oil to the nozzle body. 1) Tighten the retaining nut to 88.3 Nm {9.0 kgm}. 2) Make match marks (6) on retaining nut (2) and lower body (5). 3) Tighten the retaining nut by 45 degrees (Angle tightening). 2. Set injector assembly (1) to tool A5 . 3.

Clean the lower body and the threads of retain- ing nut (2) thoroughly with parts cleaner and blow air against them. 4. Install new nozzle assembly (3), matching it to the dowel pin of tip guide (4). a Take care not to drop the tip. 30-22 D85EX-15 (3)