STRUCTURE, FUNCTION AND MAINTENANCE STANDARD TRANMISSION ECMV Operation of ECMV The ECMV is controlled by the command current sent from the controller to the proportional sole- noid and the fill switch output signal. The relation among the proportional solenoid command current of the ECMV, the clutch input pressure, and fill switch output signal is as shown in the figure to the right. 1. Before gear shift (Region A in the diagram) When a current is not carried to the proportional solenoid (1), the pressure control valve (2) is draining the oil at the clutch port A through the drain port dr .
Since, at that time, no oil pressure acts on the oil pressure detection valve (3), the fill switch (4) is OFF. A region: Before gear shift (When draining) B region: Filling starts (During trigger) C region: Filling finishes D region: Voltage regulation E region: During filling The clutch is crimped by the piston when shifting the gear with the gear shift switch. If a high oil pressure is applied suddenly, however, the pis- ton connects to the clutch suddenly, causing the machine to make a sudden start and give an excessive shock to the machine.
To prevent them, it is designed so that if you con- nect the ECMV to shift gears with the gear shift switch, the oil pressure to the clutch may be gradually increased up to the specified level. By this design, the clutch is excited smoothly to eliminate the shock at the start, improve the durability of the power transfer system, and also provide operator comfort. D85EX-15 10-33