Komatsu — REMOVAL

DISASSEMBLY AND ASSEMBLY HSS AND WORK EQUIPMENT PUMP REMOVAL AND INSTALLATION OF HSS AND WORK EQUIPMENT PUMP ASSEMBLY REMOVAL 7. Disconnect oil pressure sensor connector HHP (4) and disconnect wiring harness clamp (5). k Disconnect the cable from the negative (–) ter- minal of the battery. 8. Disconnect TVC valve solenoid connector TVC (6). 1. Drain the oil. 6 Hydraulic tank: D85EX-15; Approx. 150 l D85PX-15; Approx. 140 l 9. Remove hose clamp bracket (7). 10. Disconnect pump hoses. (8): Discharge hose (9): LS pressure hose (10): Drain hose 2. Remove the engine hood assembly. For details, see REMOVAL OF ENGINE HOOD ASSEMBLY. 3. Remove the operator's cab assembly.

For details, see REMOVAL OF OPERATOR'S CAB ASSEMBLY. 4. Remove the floor frame assembly. For details, see REMOVAL OF FLOOR FRAME ASSEMBLY. 5. Open undercover (1). 11. Remove 4 suction tube mounting bolts (11). 12. Remove 1 pump lower mounting bolt (12). 6. Remove cover (2) and floor frame mount bracket (right side) (3). D85EX-15 30-105 (2)