DISASSEMBLY AND ASSEMBLY BLADE 7. Remove left and right trunnion caps (6). 1) Remove cover (10). 8. Remove blade assembly (7). [*2] a Run the engine and move the machine slowly in reverse to disconnect the blade assembly from the trunnion. [*2] a Adjust height b and width c of both straight frames to the following values with blocks [1], etc. Height b of trunnion: 535 mm Width of frame c : 2,762 mm 4 Blade assembly: Straight tiltdozer; D85EX-15: 3,305 kg D85PX-15: 3,343 kg Semi-tiltdozer; D85EX-15: 3,575 kg INSTALLATION Carry out installation in the reverse order to removal.
[*1] a Adjust clearance a at the cap mating sur- faces to the following value with the shim and check that the trunnion turns smoothly. Standard clearance a : 0.2 – 0.5 mm Standard shim thickness: 4 mm a After installing the blade, adjust the blade tilt- ing distance. For details, see TESTING AND ADJUSTING, Adjusting blade. Refilling with oil (Hydraulic tank) Add oil through the oil filler to the specified level. Run the engine to circulate the oil through the system. Then, check the oil level again. Bleeding air Bleed air from the work equipment cylinders. For details, see TESTING AND ADJUSTING, Bleeding air from work equipment cylinders. 30-184 D85EX-15 (2)