STRUCTURE, FUNCTION AND MAINTENANCE STANDARD HYDRAULIC, HSS PUMP Function 1. LS valve The LS valve detects the load and controls the discharge amount. This valve controls main pump discharge amount Q according to differential pressure PLS (= PP PLS ) (the difference between main pump pressure PP and control valve outlet port pressure PLS ){called the LS differential pressure}. Main pump pressure PP , pressure PLS {called the LS pressure} coming from the control valve output enter this valve. The relationship between discharge amount Q and differential pressure PLS , (the differ- ence between main pump pressure PP and LS pressure PLS ) (= PP PLS ) changes as shown in the diagram.
When the working load is heavy or the engine speed lowers, a current flows in the TVC sole- noid according to the command from the control- ler. As a result, the pump discharge (pump absorp- tion torque) is reduced to reduce the load on the engine. 3. Variable throttle valve Because the main pump controls its own prs- sure, there is a tendency for the response speed of the swash plate to be quick at high pressure and slow at low pressure. The variable throttle valve has been installed for the following reasons. (1) To reduce the swash plate speed between MIN and MAX at high pressure; to reduce the impact force on the rod and other parts of the main pump; and to prevent excessive response.
(2) To prevent cavitation at the suction port caused by the sudden increase in the suction volume when changing from MIN to MAX. 2. TVC valve When the pump discharge pressure PP is high, the TVC valve controls the pump so that no more oil than the constant flow (in accordance with the discharge pressure) flows even if the stroke of the control valve becomes larger. In this way, it carries out equal horsepower con- trol so that the horsepower absorbed by the pump does not exceed the engine horsepower.
In other words, if the load during the operation becomes larger and the pump discharge pres- sure rises, it reduces the discharge amount from the pump; and if the pump discharge pressure drops, it increases the discharge amount from the pump. The relationship between pump discharge pres- sure PP and pump discharge amount Q when this happens is shown in the diagram with the current given to the TVC valve solenoid shown as a parameter. The characteristics of the variable throttle valve are as shown in the diagram.
It has the function and property of maintaining the response during operations at low pressure by making the area of the opening smaller at high pressure and the area of the opening larger at low pressure, and by preventing the above problems (1) and (2) at high pressure. 10-50 D85EX-15