Komatsu — HYDRAULIC,HSS PUMP

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD HYDRAULIC, HSS PUMP Operation 1. LS valve (1) When control valve is at "neutral" position The LS valve is a three-way selector valve, with pressure PLS (LS pressure) from the outlet port of the control valve brought to spring chamber i , and main pump discharge pressure PP brought to chamber j of plug (6). The size of the LS pressure PLS + force F of spring (3) and the main pump pressure (self pressure) PP determines the position of spool (4). Before the engine is started, servo piston (1) is pushed to the right by spring (7) installed to rod (2).

(See the diagram on the right) When the engine is started and the control lever is at the "NEUTRAL" position, LS pres- sure PLS is 0 MPa {0 kg/cm 2 }. (It is intercon- nected with the drain circuit through the control valve spool.) At this point, spool (4) is pushed to the left, and port d and port c are connected. Pump pressure PP enters the large diameter end of the piston from port h . The same pump pressure PP also enters the small diameter end of the piston, so the swash plate is moved to the minimum angle by the difference in area of piston (1). D85EX-15 10-51