Komatsu — HYDRAULIC,HSS PUMP

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD HYDRAULIC, HSS PUMP (2) Operation in maximum direction for pump discharge amount When the difference between main pump pressure PP and LS pressure PLS, in other words, LS differential pressure PLS becomes smaller (for example, when the area of opening of the control valve becomes larger and pump pressure PP drops), spool (4) is pushed to the right by the combined force of LS pressure PLS and the force of spring (3). When spool (4) moves, port b and port c are joined and connected to the TVC valve. When this happens, the TVC valve is con- nected to the drain port, so circuit c h becomes drain pressure PT .

(The operation of the TVC valve is explained later.) For this reason, the pressure at the large pis- ton diameter end of servo piston (1) becomes drain pressure PT , and pump pres- sure PP enters the small diameter end, so servo piston (1) is pushed to the right. Therefore, rod (2) moves to the right and moves the swash plate in the direction to make the discharge amount larger. 10-52 D85EX-15