Komatsu — HYDRAULIC,HSS PUMP

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD HYDRAULIC, HSS PUMP (2) When load on actuator is small and pump discharge pressure is high When the load is large and pump dis- charge pressure PP is high, the force pushing piston (2) to the left becomes larger and piston (2) moves to the posi- tion shown in the diagram above. When this happens, as shown in the dia- gram above, part of the pressurized oil from port b flows out to port d and the pressure oil flowing from port c to the LS valve becomes approximately half of main pump pressure PP . When port h and port e of the LS valve are connected (see 1.

LS valve), the pressure from port f enters the large pis- ton diameter end of servo piston (9), and servo piston (9) stops. If main pump pressure PP increases fur- ther and piston (2) moves further to the left, main pump pressure PP flows to port c and acts to make the discharge amount the minimum. When piston (9) moves to the left, piston (5) is moved to the right by cam (7) and lever (6). For this reason, springs (3) and (4) are compressed and push back piston (2). Because of this force, piston (2) cuts of the connection from port b to port c , and port c and port d are connected. As a result, the pressure at port c (= f ) drops, and piston (9) stops moving to the left.

The position in which piston (9) stops when this happens is further to the left than the position when pump pressure PP is low. D85EX-15 10-57