STRUCTURE, FUNCTION AND MAINTENANCE STANDARD HYDRAULIC, HSS PUMP b. Movement of spring The spring load of springs (3) and (4) in the TVC valve is determined by the swash plate position. When servo piston (9) moves, cam (7), which is connected to rod (8), also moves. When this happens, lever (6) is rotated by the angle of cam (7), and posi- tion (5) moves to the right and left. If piston (5) moves to the right, spring (3) is compressed, and if it moves further to the right, spring (4) contacts seat (10), so both spring (3) and spring (4) function. In other words, the spring load is changed by piston (5) extending or con- tacting springs (3) and (4).
If the command current input to solenoid (1) changes further, the force pushing solenoid push pin (11) changes, and the spring load of springs (3) and (4) also changes according to the value of the solenoid command current. Port c of the TVC valve is connected to port e of the LS valve (see 1. LS valve). Self pressure PP enters port b , the small piston diameter end of servo piston (9), and port a . When pump pressure PP is small, piston (2) is on the right. At this point, port c and port d are con- nected, and the pressure entering the LS valve becomes drain pressure PT . If port h and port e of the LS valve are connected (see 1.
LS valve), the pres- sure entering the large piston diameter end from port f becomes drain pressure PT , and servo piston (9) moves to the right. In this way, the pump discharge amount moves in the direction of increase. As servo piston (9) moves further, piston (5) is moved to the left by rod (8), cam (7) and lever (6). Springs (3) and (4) expand and the spring force becomes weaker. When the spring force becomes weaker, piston (2) moves to the left, so the con- nection between port c and port d is cut, and the pump discharge pressure is con- nected to port b .
As a result, the pressure at port c rises, and the pressure at the large piston diameter end also rises, so the move- ment of piston (9) to the right is stopped. In other words, the stop position for pis- ton (9) (= pump discharge amount) is decided at the point where for the force of springs (3) and (4) and the pushing force from the solenoid and the pushing force created by pressure PP acting on piston (2) are in balance. 10-56 D85EX-15