STRUCTURE, FUNCTION AND MAINTENANCE STANDARD HYDRAULIC, HSS PUMP 2. TVC valve (1) When transmission, steering controller is normal 1) When the load on the actuator is small and pump pressure PP is low a. Movement of solenoid (1) The command current from the transmis- sion, steering controller flows to solenoid (1). This command current changes the internal force pushing solenoid push pin (11). On the opposite side to the force pushing this solenoid push pin (11) is the spring set pressure of springs (3) and (4) and pump pressure PP .
Piston (2) stops at a position where the combined force pushing piston (2) is bal- anced, and the pressure (pressure of port c ) output from the TVC valve changes according to this position. The size of command current X is deter- mined by the nature of the operation (lever operation), the selection of the working mode, and the set value and actual value for the engine speed. D85EX-15 10-55