Komatsu — HYDRAULIC,HSS PUMP

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD HYDRAULIC, HSS PUMP (4) When servo piston is balanced Let us take the area receiving the pressure at the large piston diameter end as A1 , the area receiving the pressure at the small diameter end as A0 , and the pressure flowing into the large piston diameter end as Pen . If the main pump pressure PP of the LS valve and the combined force of force F of spring (3) and LS pressure PLS are bal- anced, and the relationship is A0 x PP = A1 x Pen . The servo piston (1) will stop in that position, and the swash plate will be kept at an inter- mediate position.

(It will stop at a position where the opening from port b to port c and from port d to port c of spool (4) is approxi- mately the same.) At this point, the relationship between the area receiving the pressure at both ends of piston (1) is A0 : A1 = 1:2, so the pressure applied to both ends of the piston when it is balanced becomes PP : Pen Pen 2:1. The position where spool (4) is balanced and stopped is the standard center, and the force of spring (3) is adjusted so that it is deter- mined when PP PLS = 1.96 MPa {20 kg/ cm 2 }. 10-54 D85EX-15