140 Maintenance Section Walk-Around Inspection 101105559 NOTICE Accumulated grease and/or oil on an engine or deck is a fire hazard. Remove this debris with steam cleaning or high pressure water. e@ Ensure that cooling lines are properly clamped and tight. Check for leaks. Check the condition of all pipes. ® Inspect the water pumps Note: The water pump for coolant leaks. seal is lubricated by coolant in the cooling system. It is normal for a small amount of leakage to occur when the engine coois and the parts contract. Walk-Around Inspection (Exercise Inspection of Standby Generator Set Engines) SMCS Code: 1000-040 1.
Perform the procedures that are described in this Operation and Maintenance Manual, “Before Starting Engine” topic (Operation Section). 2. Start the engine according to the instructions in this Operation and Maintenance Manual, “Engine Starting” topic (Operation Section). Excessive coolant leakage may indicate the need to replace the water pump seal. For the removal of NOTICE water pumps and the installation of water pumps For any type of leak (coolant, lube, or fuel) clean up the and/or seals, refer to the Service Manual engine or consult your Caterpillar dealer. fluid. If leaking is observed, find the source and correct the leak.
If leaking is suspected, check the fluid levels more often than recommended until the leak is found or fixed, or until the suspicion of a leak is proved to be for the ® Inspect the lubrication system for leaks at the front crankshaft seal, the rear crankshaft seal, the unwarranted. oil pan, the oil filters and the valve cover. ® Inspect the fuel system for leaks. Look for loose fuel line clamps. ® Inspect the piping for the air inlet system and the elbows for cracks and for loose clamps. e Drain the water and the sediment from fuel tanks on a daily basis in order to ensure that only clean fuel enters the fuel system.
e Inspect the wiring and the wiring harnesses for loose connections and for worn wires or frayed wires. e Inspect the ground strap for a good connection and for good condition. e Check the condition of the gauges. Replace any gauge that is damaged. Replace any gauge that can not be calibrated. ® Inspect the exhaust system for leaks. Inspect the gaskets and the exhaust bellows joint. If a leak is found, make repairs. 3. Perform an inspection of the installation after the engine is started. Look for leaks. Listen for unusual noises. @ Check the engine oil level when the engine is operating at low idle rom. Observe the oil level on the “LOW IDLE” side of the oil level gauge (dipstick).
e Inspect the lubrication system for leaks at the oil pan, the oil filter, and the valve covers. ® Inspect the cooling system for leaks at the hose connections. e Inspect the piping for the air inlet system and the elbows for cracks and for loose clamps. ® Inspect the exhaust system for leaks. e If the enclosure has louvers, louvers for proper operation. inspect the e Observe the gauges. Ensure the correct readings for the engine rpm. Record the data for the gauges. e Record the data for the performance of the generator. See the Operation and Maintenance Manual for the generator and the control panel.