Caterpillar — ENGINE FEATURES AND CONTROLS

38 Operation Section Engine Features and Controls e Warning Table 11 Altitude e Derating The strategy is applied to the right side air filter and/or the left side air filter. The default settings that are programmed at the factory are listed in Table 10. Table 10 Parameter Default Setting Derate setpoint 2T specification Security level Required password Derating per 305 m Maximum derating (1000 ft) Inlet Air Restriction ] 3% 3 35% of the rated power Parameter Default Setting Warning setpoint 7 kPa (1 psi) If the barometric Warning delay 5 seconds warning and a derating will occur.

The continuous schedule of the derating is three percent per Derate setpoint 7 kPa (1 psi) Derate delay 5 seconds Security level Password required Derating per 1 kPa (.15 psi) 2% Maximum restriction 25 kPa (3.6 psi) L pressure is below the setpoint, a 1 kPa (.15 psi) of pressure below the setpoint. The maximum derating is 35 percent. Exhaust Temperature The ECM will automatically perform the following functions if a high exhaust temperature occurs: If the inlet air restriction is above 7 kPa (1 psi) for five seconds, both a warning and a derating will e Warning occur. The continuous schedule of the derating is e Derating two percent per 1 kPa (0.15 psi).

The maximum derating is 50 percent at 25 kPa (3.6 psi. The strategy is applied to the right side exhaust The derating remains at the maximum level until the default settings that are programmed situation is corrected. To reset the derating to zero percent, remove power from the ECM. The ECM will reset when power is returned. manifold and/or the left side exhaust manifold. The Table 12 Exhaust Altitude The ECM automatically compensates for engine operation at higher elevations. The ECM derates the fuel delivery according to the barometric pressure. The barometric pressure is sensed by the atmospheric pressure sensor. The atmospheric pressure has an effect on the performance of the engine.

Derating the fuel delivery maintains the temperatures of the exhaust gas within acceptable limits. barometric pressure. The barometric pressure is equal to the atmospheric pressure of an elevation. The atmospheric pressure is specific for the engine and for the engine rating. The default settings that Temperature Parameter Default Setting Warning setpoint 2T specification Warning delay 5 seconds Derate setpoint 2T specification Derate delay 5 seconds Delay per step 15 seconds Hysteresis Security level The derating of the engine starts at a specific at the factory are listed in Table 12.

Derating per step 10 °C (18 °F) Required password 2% per step If the exhaust temperature is above the setpoint for the warning for five seconds, a warning will occur. are programmed at the factory are listed in Table 11. If the exhaust temperature is above the setpoint for the derating for five seconds, the derating will occur. The derating reduces the power by two percent. This is followed by a 15 second delay. If the exhaust temperature is not reduced below the setpoint after the 15 second delay, the engine is derated another two percent.