Caterpillar — ENGINE FEATURES AND CONTROLS

39 Operation Section Engine Features and Controls When the exhaust temperature is reduced to less than the setpoint, two percent of the power is restored for every 15 seconds. This continues until full power is restored. However, if the exhaust temperature rises above the setpoint again, the derating resumes. Oil Filter Differential Pressure e Derating @ Shut down The default settings that are programmed at the factory are listed in Table Table 15 Crankease The ECM automatically warns the operator of high oil filter differential pressure. The default settings that are programmed at the factory are listed in Table 12.

Table 13 Oil Filter Differential Pressure Parameter Pressure Parameter Default Setting Warning setpoint 2 kPa (.3 psi) Warning delay 3 seconds Derate setpoint 6 kPa (.9 psi) Derate 10 seconds delay Default Setting Maximum time of derating 480 seconds 105 kPa (15 psi) Hysteresis 0.25 kPa (.036 psi) Warning delay 5 seconds Security level Required password Hysteresis 10 kPa (1.5 psi) Security level No required password Warning ] 15. setpoint lf the oil filter differential pressure is above 105 kPa (15 psi) for five seconds, a warning will occur. To deactivate the warning, the oil filter differential pressure must be below 95 kPa (13.5 psi).

Fuel Filter Differential Pressure The ECM automatically warns the operator of high fuel filter differential pressure. The default settings that are programmed Table 14. at the factory are listed in Table 14 Fuel Filter Differential Pressure Parameter Default Setting Warning setpoint 105 kPa (15 psi) Warning delay 5 seconds Hysteresis 10 kPa (1.5 psi) Security level No required password lf the fuel filter differential pressure is above 70 kPa (10 psi) for five seconds, a warning will occur. To deactivate the warning, the fuel filter differential pressure must be below 60 kPa (8.7 psi).

Crankcase Pressure e Warning derating Shutdown setpoint Shutdown delay 25% 3.5 kPa (.51 psi) 3 seconds \f the crankcase pressure is above 2 kPa (.3 psi) for three seconds, a warning will occur. To deactivate the warning, the crankcase pressure must be below 1.75 kPa (.254 psi). If the crankcase pressure is above 6 kPa (.9 psi) for 10 seconds, a derating will occur. The continuous schedule of the derating will reach 15 percent in 480 seconds. When the crankcase pressure is less than 5.75 kPa (.39 psi), the percent of the derating is decreased until full power is restored. However, if the crankcase pressure rises above the setpoint again, the derating resumes.

If the crankcase pressure is above 3.5 kPa (.51 psi) for three seconds, a shutdown will occur. Note: The default settings result in a shutdown that occurs before a derating. These settings were selected for the reason that high crankcase pressure can occur rapidly. The settings can be reprogrammed. Aftercooler Coolant Temperature Note: The following information concerns engines The ECM will automatically perform the following functions if high crankcase Maximum pressure occurs: with separate circuit aftercooling. For engines with jacket water aftercooling, monitoring of the aftercooler coolant temperature is disabled.

However, the jacket water coolant temperature is monitored for all engines.