Komatsu D155AX-6 — TORQUE CONVERTER, PTO

SEN00604-00 10 Structure, function and maintenance standard Oil flow q The oil flows through the main relief valve and its pressure is reduced to below the set pres- sure by the torque converter relief valve. It then flows in inlet port (A), goes through the oil pas- sages of torque converter case (1), stator clutch front housing (2), pump shaft (3) and retainer (4), and flows into pump (5). q The oil is given centrifugal force by pump (5) and flows in turbine (6) to transfer its energy to turbine (6). q The oil from turbine (6) is sent to stator (7) and flows into pump (5) again.A part of the oil, how- ever, is sent through outlet port (B) to the power train oil cooler. 18 D155AX-6