Komatsu D155AX-6 — E-22 MACHINE MONITOR CANNOT BE SET IN SERVICE MODE

SEN00807-01 40 Troubleshooting E-21 When starting switch is turned OFF, service meter is not displayed 1 E-22 Machine monitor cannot be set in service mode 1 46 D155AX-6 Trouble • When starting switch is turned OFF, service meter is not displayed. Related information • While starting switch is at OFF position, if following switches are operated, service meter is dis- played at top center of screen. Operation of switches:

[4] + [1] (Press simultaneously) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective backup power sup- ply system When starting switch is turned ON, if machine monitor displays nothing, backup power supply system may be defective. In this case, carry out troubleshooting for "E-1 When starting switch turned ON, machine monitor displays nothing". 2 Defective machine monitor If cause 1 is not detected, machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) Trouble • Machine monitor cannot be set in service mode.

Related information • If following switches are operated, machine monitor is set in service mode. Operation of switches: [4] + [1] o [2] o [3] (While pressing [4], press other switches in order) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective machine monitor Machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)