SEN00807-01 40 Troubleshooting E-23 Ripper pin puller cylinder does not operate 1 48 D155AX-6 Trouble (1) When pin puller switch is pulled out, cylinder is not retracted. (2) When pin puller switch is pushed in, cylinder is not extended. Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse(FS2-3) If fuse is broken, circuit probably has ground fault (See cause 5). 2 Defective pin puller switch a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. PLSW (male) Pin puller switch Resistance Between (1) – (2) Pulled out Max. 1 z Pushed in Min.
1 Mz 3 Defective pin puller solenoid a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. PPL (male) Resistance Between (1) – (2) 10 – 80 z Between (1) – chassis ground Min. 1 Mz 4 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between FS22 (3) – PLSW (female) (1) Resis- tance Max. 1 z Wiring harness between PLSW (female) (2) – PPL (female) (1) Resis- tance Max. 1 z Wiring harness between PLSW (female) (2) – chassis ground (GND03) Resis- tance Max.
1 z 5 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between FS22 (3) – PLSW (female) (1) or circuit branch end and chas- sis ground Resis- tance Min. 1 Mz Wiring harness between PLSW (female) (2) – PPL (female) (1) and chassis ground Resis- tance Min. 1 Mz 6 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between FS22 (3) – PLSW (female) (1) or circuit branch end and chas- sis ground Voltage Max.
1 V Wiring harness between PLSW (female) (2) – PPL (female) (1) and chassis ground Voltage Max. 1 V