Komatsu D155AX-6 — REMOVAL AND INSTALLATION OF POWER TRAIN UNIT ASSEMBLY

50 Disassembly and assembly SEN01206-00 Removal and installation of power train unit assembly 1 5. Disconnect hoses (4) through (7). Removal 6. Disconnect hoses (8) through (11), and remove hose clamps (12) and (13). k Park the machine at the level place, lower the work equipment fully to the ground, and disconnect the negative terminal (–) of the battery. 1. Drain the oil from hydraulic tank and power train case. 6 Hydraulic tank: 85 l Power train case: 90 l 2. Remove floor frame assembly referring to the section, "Removal and installation of floor frame assembly". 3. Disconnect connectors PUMP (1) and HSS (2) at power train unit right side. 7.

Disconnect hoses (14) and (15) at the rear of hydraulic tank. 8. Remove oil level gauge (16) and oil filler tube (17). 9. Remove clamps (18) through (20), and remove hose. 4. Disconnect 13 hoses (3) of split flange from control valve. D155AX-6 11