Komatsu D155AX-6 — MAIN RELIEF VALVE AND TORQUE CONVERTER RELIEF VALVE

10 Structure, function and maintenance standard SEN00604-00 Outline Operation of main relief valve Torque converter relief valve q The torque converter relief valve maintains the oil pressure in the torque converter inlet circuit always below the set pressure in order to pro- tect the torque converter from abnormally high pressure. Set pressure: 1.06 ± 0.05 MPa {10.8 ± 0.5 kg/cm 2 } (Cracking pressure) q The main relief valve is keeping each hydraulic circuit of the transmission and the parking brake at set pressure. Set pressure:

3.18 ± 0.1 MPa {32.4 ± 1.0 kg/cm 2 } (Engine at rated speed) Main relief valve q The oil from the hydraulic pump flows to cham- ber (F) through the filter, port (C) of the relief valve and orifice (a) of main relief valve (1). Operation Operation of torque converter relief valve q As the oil pressure in the circuit goes beyond the set pressure, the oil conducted to chamber (F) pushes piston (2) and the resulting reaction force pushes spool (1) leftward, opening ports (C) and (E). Above operation conducts the oil from port (E) to the torque converter.

q The oil from the main relief valve is conducted to the torque converter through port (E) and, at the same time, also conducted to chamber (G) through orifice (b) of torque converter relief valve (3). q As the oil pressure to the torque converter rises beyond the set pressure, the oil con- ducted to chamber (G) pushes piston (4) and the resulting reaction force pushes torque con- verter relief valve (3) rightward, opening ports (E) and (A). As the result, the oil in port (E) is drained through port (A). D155AX-6 47