Komatsu D155AX-6 — SCAVENGING PUMP

10 Structure, function and maintenance standard SEN00604-00 Scavenging pump 1 Type: SAR(4)140 Unit: mm Outline q The scavenging pump is installed to the torque converter case and is driven with the power from the engine. It returns the oil collected in the bottom of the transmission case to the steering case. D155AX-6 49 No. Check item Criteria Remedy 1 Side clearance Standard clearance Clearance limit Replace 0.11 – 0.16 0.19 2 Clearance between plain bear- ing inner diameter and gear shaft outer diameter 0.06 – 0.14 0.20 3 Pin driving depth Standard size Tolerance Repair limit 21 -0.5 -0.5 — 4 Spline shaft rotating torque 9.8 – 14.7 Nm {1.0 – 1.5 kgm} — – Delivery amount Oil:

SAE10WCD Oil temperature: 45 – 55°C Rotation speed (rpm) Delivery pressure MPa{kg/cm2} Standard delivery (l/min) Delivery limit (l/min) 2,200 2.94{30} 300 266