10 Structure, function and maintenance standard SEN00605-00 Operation 1) When the control valve is situated at neutral q The LS valve is a three-way selector valve, with pressure (PLS) (LS pressure) from the inlet port of the control valve brought to spring chamber (B), and pump discharge pressure (PP) brought to port (H) of sleeve (8). q The same pump discharge pressure (PP) enters the small diameter end of piston port (J). q Because of the difference in area of servo pis- ton (10), it moves in the direction to make the swash plate angle smaller.
q Magnitude of the force resulting from this LS pressure (PLS), force of spring (4) and the pump delivery pressure (self pressure) (PP) determine the position of spool (6). q Before the engine is started, servo piston (10) is pushed to the right.(See right drawing) q If the control lever is at the neutral position when the engine is started, LS pressure (PLS) will be set to 0 MPa {0 kg/cm 2 }. (It is intercon- nected to the drain circuit through the control valve spool) q Spool (6) is pushed to the right, and port (C) and port (D) will be connected. q Pump discharge pressure (PP) enters the large diameter end of piston from port (K). D155AX-6 21