Komatsu D155AX-6 — HYDRAULIC, HSS PUMP

SEN00605-00 10 Structure, function and maintenance standard 4) When servo piston is balanced q Let us take the area receiving the pressure at the large diameter end of the piston as (A1), the area receiving the pressure at the small diameter end as (A0), and the pressure flowing into the large diameter end of the piston as (PEN). q The position where spool (6) is balanced and stopped is the standard center, and the force of spring (4) is adjusted so that it is determined when (PP) – (PLS) = 1.96 MPa {20kg/cm 2 }.

q If pump discharge pressure (PP) of the LS valve and the combined force of spring (4) and LS pressure (PLS) are balanced, and the rela- tionship becomes (A0) x (PP) = (A1) x (PEN), servo piston (10) stops at that position. q And the swash plate of the pump will be held in an intermediate position. [Spool (6) will be stopped at a position where the distance of the opening from port (D) to port (E) and the dis- tance from port (C) to port (D) is almost the same.] q The relationship between the area receiving the pressure at both ends of servo piston (10) is (A0):(A1) = 3:5, so the pressure applied to both ends of the piston when it is balanced becomes (PP):(PEN) C 5 : 3. 24 D155AX-6