Komatsu D155AX-6 — HYDRAULIC, HSS PUMP

SEN00605-00 10 Structure, function and maintenance standard (2) When the load on the actuator is large and pump discharge pressure (PP) is high q When the load is large and pump discharge pressure (PP) is high, the force pushing spool (3) to the right becomes larger and spool (3) moves to the position shown in the diagram above. Outline Operation q When port (E) and port (G) of the LS valve are connected, this pressure from port (J) enters the large diameter end of servo piston (9), stopping servo piston (9).

q As shown in the diagram above, part of the pressurized oil from port (B) flows out to port (D) from port (C) through the LS valve, and the pressure oil flowing from port (C) to the LS valve becomes approximately half of pump dis- charge pressure (PP). q If pump discharge pressure (PP) increases fur- ther and spool (3) moves further to the right, pump discharge pressure (PP) flows to port (C) and acts to make the delivery the mini- mum. q If servo piston (9) moves to the right, spring (4) is compressed and push back spool (3). q When spool (3) moves to the left, the openings of port (C) and port (D) become larger.

q The pressure on port (C) (= J) is decreased and the rightward move of servo piston (9) is stopped. q The position in which servo piston (9) stops when this happens is further to the right than the position when pump discharge pressure (PP) is low. 30 D155AX-6