Komatsu D155AX-6 — QUICK DROP VALVE

10 Structure, function and maintenance standard SEN00607-00 2. Circulating condition q Lowering blade (Stroke of lever is more than 70%.) q QDV mode: ON Operation q The pressurized oil which has been flowing to port (PB) merges with the pressure oil from port (VB) and flows into the lift cylinder bottom. q 1,000 mA of command current (X) flows from controller to EPC valve and the pilot pressure from the EPC valve is taken to chamber (a) at the main spool. q The blade lowering speed is increased by the quantity of oil flowing into the lift cylinder bot- tom.

q Main spool (1) moves to the right and the cir- cuits between port (VH) and port (PH)/port (VB) and port (PB), get into circulating condi- tion. q Vacuum on the lift cylinder bottom is pre- vented. q Most of the pressurized oil which has been flowing from port (PH) to port (VH), circulates and flows to port (PB). D155AX-6 59