Komatsu D155AX-6 — 30 TESTING AND ADJUSTING

20 Standard value table SEN00678-01 Standard value table for machine 1 D155AX-6 3 Machine model D155AX-6 Cate- gory Item Measurement condition Unit Standard value for new machine Service limit value Engine speed Decelerator pedal speed • Engine coolant temperature: Within operating range • Power train oil temperature: Within operating range • Hydraulic oil temperature: Within operating range • Engine: High idle • Decelerator pedal speed: Press pedal • Auto deceleration speed: Set all levers in neutral rpm 875 ± 50 875 ± 50 Auto deceleration speed rpm 1,875 ± 50 1,875 ± 50 Torque converter stall speed • Engine coolant temperature: Within operating range • Power train oil temperature:

Within operating range • Hydraulic oil temperature: Within operating range • Engine: High idle • Select P mode • Torque converter stall speed: F3 • Torque converter stall speed + Work equipment relief speed: F3 + Ripper raise rpm 1,610 ± 50 1,450 Torque converter stall speed + Work equipment relief speed rpm 1,550 ± 50 1,395 Cooling fan Fan motor speed • Hydraulic oil temperature: Within operating range • Fan: Set in 100% mode • Engine: Low idle Min. speed rpm — — • Hydraulic oil temperature: Within operating range • Fan: Set in 100% mode • Engine: High idle Max. speed rpm 1,250 ± 50 1,250 ± 50 Fan pump circuit pressure • Hydraulic oil temperature: Within operating range • Fan:

Set in 100% mode • Engine: High idle MPa {kg/cm2} Stroke of control lever/pedal PCCS lever Forward/ Reverse travel • Stop engine • Center of lever grip N o Forward mm 30 ± 5 30 ± 5 N o Reverse mm 30 ± 5 30 ± 5 Steering N o Left mm 40 ± 5 40 ± 5 N o Right mm 40 ± 5 40 ± 5 Decelerator pedal • Stop engine • Center of pedal mm 50 ± 10 50 ± 10 Brake pedal • Engine: Low idle • Center of pedal All stroke mm 79 ± 10 79 ± 10 Stroke to 0 of oil pressure mm 54 ± 4 54 ± 4