SEN00679-01 30 Testing and adjusting Measuring exhaust temperature 1 a Measuring instruments for exhaust tempera- ture k Stop the machine on level ground, lower the work equipment to the ground, stop the engine, and set the parking brake lever and work equipment lock lever in the lock posi- tion. k Install and remove the measuring instru- ments after the exhaust manifold is cooled. a Measure the exhaust temperature under the following conditions. q Engine coolant temperature: Within oper- ating range 4. When measuring maximum exhaust tempera- ture for troubleshooting Operate the machine actually and measure the maximum exhaust temperature. a Use the PEAK mode of the thermometer.
a The exhaust temperature largely depends on the outside air temperature (intake air temperature of the engine). Accordingly, if any abnormal value is obtained, correct it by the following calculation. q Power train oil temperature: Within operat- ing range q Hydraulic oil temperature: Within operat- ing range 1. Open the engine right side cover and right mudguard. 2. Remove 1 exhaust temperature pickup plug (1) from the exhaust manifold. a You may measure the exhaust tempera- ture at either front or rear plug. q Corrected value [°C] = Measured value + 2 Ч (20 – Outside air tempera- ture) 5.
Procedure for measuring exhaust temperature periodically for preventive maintenance (Pm clinic) a If the torque converter is stalled simply, the torque converter oil is overheated before the exhaust temperature is stabi- lized. Accordingly, measure according to the following procedure. 1) Turn the starting switch ON and set the machine monitor to Adjustment function of the service mode. 3. Install sensor [1] of digital thermometer B and connect them to meter [2]. a Clamp the wiring harness of the digital thermometer so that it will not touch a hot part during measurement. q Adjustment code: 0530 (Stall mode) a For the operating method, see Spe- cial functions of machine monitor (EMMS).
8 D155AX-6 Symbol Part No. Part name B 799-101-1502 Digital thermometer