Komatsu D155AX-6 — MEASURING EXHAUST TEMPERATURE

30 Testing and adjusting SEN00679-01 2) Start the engine and set the fuel control dial in the low idle (MIN) position. 3) Operate the shiftup (UP) switch of the PCCS lever and set the preset mode dis- play section to [F3-R3]. a The preset mode display section (at the right bottom of the screen) can be set to [F3-R3] only while the Adjust- ment function is selected. 4) Set the work equipment lock lever in the free position and operate the ripper control lever to set the ripper lift cylinder to the raise stroke end. 5) While pressing the brake pedal securely, set the parking brake lever in the free position and set the direction of PCCS lever in the forward position.

a Before going to the next step, check that [F3] is displayed in the gear speed display section (at the right bottom of the screen). a Keep the steering system in neutral. 6) Press the decelerator pedal and set the fuel control dial in the high idle (MAX) position. 7) Return the decelerator pedal slowly to stall the torque converter and relieve the ripper raise system to raise the exhaust temper- ature to about 650 °C (Condition (a) in the figure) with the engine at high idle. 8) Under the condition of step 7), stop reliev- ing the ripper raise system and lower the exhaust temperature by only stalling the torque converter (Condition (b) in the fig- ure).

a If the exhaust temperature does not lower but rises, set the temperature high in step 7). 9) After the exhaust temperature is lowered and stabilized, measure the exhaust tem- perature (Condition (c) in the figure). k Just after the power train oil tem- perature (T/C TEMPERATURE) reaches about 120 °C, return the direction of PCCS lever to neutral and lower the power train oil tem- perature with the engine at high idle. a The border between the green range and red range of the power train oil temperature gauge indicates about 120 °C. k Keep pressing the brake pedal securely and keep your right foot on the decelerator pedal for safety until the work is finished. 6.

After finishing measurement, remove the mea- suring instruments and return the removed parts. D155AX-6 9