30 Testing and adjusting SEN00679-01 1. Preparation work 1) Open the engine left side cover and left mudguard. 2) Remove tube (3) between supply pump (1) and common rail (2). a In the figure, 1 oil filter is removed temporarily from the common rail side. a Disconnect both ends of the tube, loosen the clamp, and move the tube to the opposite side of the cylinder block. 5) Connect test hose J3 to the end of joint J2 . a Bind the connecting part of the test hose with a wire, etc. to prevent it from coming off. a The above is the preparation work for measuring the leakage from the pres- sure limiter. 2.
Testing leakage from pressure limiter 1) Lay test hose J3 so that it will not slacken and put its end in the oil pan. 2) Turn the starting switch ON and set the machine monitor to Monitoring function of the service mode. 3) Insert spacer J1 on supply pump (1) side and tighten the removed joint bolt again. a Connect the return pipe to the fuel tank again, too. a Be sure to fit the gaskets to both ends of the spacer. q Monitoring code: 01002 Engine Speed a For the operating method, see "Spe- cial functions of machine monitor (EMMS)". 4) Insert joint J2 on common rail (2) side and tighten the removed joint bolt again.
a In the figure, 1 oil filter is removed temporarily from the common rail side. a Be sure to fit the gaskets to both ends of the joint. D155AX-6 19