SEN00679-01 30 Testing and adjusting 3) Run the engine at high idle and stall the torque converter. After the engine speed is stabilized, measure the leakage in 1 minute with measuring cylinder J5 . a For the procedure for stalling the torque converter, see Measuring torque converter stall speed. a You may measure the leakage for 20 seconds and judge by multiplying the result by 3. a If the leakage from the pressure lim- iter is in the following range, it is nor- mal. 2) Lay test hose J4 so that it will not slacken and put its end in the oil pan. Engine speed Leakage (cc/min) Torque converter stall Max.
10 3) Turn the starting switch ON set the machine monitor to Adjusting function of the service mode. q Adjustment code: 0530 (Stall mode) a For the operating method, see "Spe- cial functions of machine monitor (EMMS)". 4) After finishing measurement, stop the engine. 3. Testing return rate from injector a Keep the hose on the pressure limiter side connected and keep its end in the oil pan while measuring the return rate from the injector. 1) Disconnect return hose (5) of return block (4) and connect test hose J4 . a Stop the return hose with a plug, etc. and fix it to the fuel tank. Plug: 07376-70315 a Bind the connecting part of the test hose with a wire, etc. to prevent it from coming off.
20 D155AX-6