Komatsu D155AX-6 — MEASURING FAN SPEED

30 Testing and adjusting SEN00679-01 Measuring fan speed 1 a If this adjustment code is displayed, the fan speed is kept at 100% speed in accor- dance with the engine speed, regardless of the state of the machine. a Measuring instrument for fan speed k Stop the machine on level ground, lower the work equipment to the ground, stop the engine, and set the parking brake lever and work equipment lock lever in the lock posi- tion. a Measure the fan motor speed under the follow- ing condition. q Hydraulic oil temperature: Within operat- ing range 1. Open the radiator mask and remove the fan net. 6. While running the engine at low idle and high idle, measure the fan speed 2.

Stick 1 reflection tape [1] of tachometer kit K to fan (1) 3. Set probe [2] to the reflection tape with stand [3] and connect it to tachometer [4]. k Take care that the probe will not inter- fere with the fan. a Rotate the fan with the hand and check that the probe can sense the rotation of the reflection tape. 7. After finishing measurement, remove the mea- suring instruments and return the removed parts. 4. Close the radiator mask. k Before starting the engine, be sure to close the radiator mask. Do not start the engine while the radiator mask is open. 5. Start the engine and set the machine monitor to Adjusting function of the service mode. a Adjustment code:

1005 (Fan 100% mode) a For the operating method, see "Special functions of machine monitor (EMMS)". D155AX-6 27 Symbol Part No. Part name K 795-205-1100 Tachometer kit