SEN00680-01 30 Testing and adjusting Measuring ripper pin puller solenoid valve output pressure 1 a Measuring instruments for ripper pin puller solenoid valve output pressure k Stop the machine on level ground, lower the work equipment to the ground, stop the engine, and set the parking brake lever and work equipment lock lever in the LOCK position. a Measure the ripper pin puller solenoid valve output pressure under the following condition. 4. Run the engine at high idle, set the pin puller switch in the pull-out position and push-in posi- tion, and measure the solenoid valve output pressure at each position.
a If the output pressure is as follows, the operation of the ripper pin puller solenoid valve is normal. q Power train oil temperature: Within operating range 1. Remove the undercover of the fuel tank and disconnect ripper pin puller solenoid valve hose (1) or (2). q Hose (1): Pin puller cylinder head side q Hose (2): Pin puller cylinder bottom side 2. Install adapter U2 and connect the discon- nected hose again. 3. Install nipple [1] of hydraulic tester U1 and con- nect oil pressure gauge [2]. a When using an analog oil pressure gauge, use one of 5.9 MPa {60 kg/cmІ}. 5. After finishing measurement, remove the mea- suring instrument and return the removed parts. 30 D155AX-6 Symbol Part No.
Part name U 1 799-101-5002 Hydraulic tester 790-261-1204 Digital hydraulic tester 2 799-401-3200 Adapter (03) Tested hose Pin puller switch Output pressure (1) Pull-out Same as transmission main relief pressure (See standard value table) Push-in 0 MPa {0 kg/cm²} (2) Pull-out 0 MPa {0 kg/cm²} Push-in Same as transmission main relief pressure (See standard value table)