30 Testing and adjusting SEN00680-01 Releasing residual pressure from work equipment cylinder 1 Bleeding air from work equipment cylinder 1 a When disconnecting the piping between the control valve and work equipment cylinder, release the residual pressure from the circuit according to the following procedure. a If the work equipment cylinder is removed and installed or its piping is disconnected and con- nected, bleed air from its circuit according to the following procedure. a Before performing the following operation, check that the hydraulic oil level is normal.
k Stop the machine on level ground, lower the work equipment to the ground, stop the engine, and set the parking brake lever and work equipment lock lever in the LOCK position. 1. Run the engine at low idle for about 5 minutes. 2. While running the engine at low idle, extend and retract the cylinder to be bled 4 – 5 times. a Move the piston rod to about 100 mm before the stroke end and never relieve the oil. 1. Loosen oil filler cap (1) of the hydraulic tank gradually to release the residual pressure from the tank. 3. While running the engine at high idle, carry out the operation in step 2. 4. While running the engine at low idle, move the cylinder to the stroke end to relieve the oil. 2.
Turn the starting switch ON and set the work equipment lock lever in the FREE position. 3. Operate the blade control lever and ripper control lever to each direction. a If the control lever is operated 2 – 3 times, the residual pressure in the accumulator is released. 4. Run the engine at low idle for about 10 sec- onds to increase the pressure in the accumula- tor, then stop it. 5. Repeat steps 2 – 4 above 2 – 3 times. D155AX-6 33