Komatsu D155AX-6 — ADJUSTING WORK EQUIPMENT LOCK LEVER

SEN00680-01 30 Testing and adjusting Adjusting work equipment lock lever 1 k Stop the machine on level ground, lower the work equipment to the ground, stop the engine, and set the parking brake lever and work equipment lock lever in the LOCK position. a Tighten the locknut of the rod securely and bend the cotter pin securely. a When adjusting the work equipment lock lever, remove the control valve cover. a Monitoring code: 70300 Blade Sw Input a For the operating method, see Special functions of machine monitor (EMMS). 4 Control valve cover: 25 kg 1. Set work equipment lock lever (1) in the LOCK position. 2. Set and install limit switch (2) to sliding surface (a) of lever (3).

a Just set the roller of the limit switch to the sliding surface. Do not move it. 5. Check that the limit switch signal is input nor- mally when work equipment lock lever (1) is set in the FREE position and LOCK position. 3. Set work equipment lock lever (1) in the FREE position and check that limit switch (2) oper- ates normally. q FREE position: Work equipment lock NC OFF, Work equipment lock NO ON q Stroke of limit switch: 2.5 – 3 mm q LOCK position: Work equipment lock NC ON, Work equip- ment lock NO OFF 4. Turn the starting switch ON and set the machine monitor to Monitoring function of the service mode. 34 D155AX-6