30 Testing and adjusting SEN00681-01 "Abnormality Record" (Electrical system "Abnor- mality Record") The machine monitor classifies and records the abnormality which occurred in the past or which are occurring at present into the mechanical system abnormality, electrical system abnormality, and air conditioner abnormality or heater abnormality. To check the electrical system "Abnormality Record", perform the following procedures. 3. Information displayed on "Abnormality Record" screen On the "Electrical Systems" screen, the follow- ing information is displayed.
(a):Occurrence order of abnormality from lat- est one/Total number of records (b):Failure code (c):Contents of trouble (d):Number of occurrence time (e):Service meter reading at first occurrence (f): Service meter reach at last occurrence 1. Selecting menu Select "02 Abnormality Record" on the "Ser- vice Menu" screen. q [F1]: Move to next page (screen) (if dis- played) q [F2]: Move to previous page (screen) (if displayed) q [F3]: Move to lower record q [F4]: Move to upper record q [F5]: Return to "Abnormality Record" screen a If no "Abnormality Record" is recorded, "No Abnormality Record" is displayed.
a If the number of occurrence time is 1 (first occurrence), the service meter reading at the first occurrence and that at the last occurrence are the same. a If [E] is displayed on the left of a failure code, the abnormality is still occurring or resetting of it has not been confirmed. a For all the failure codes that the machine monitor can record, see the failure codes table. 2. Selecting sub menu After the "Abnormality Record" screen is dis- played, select "02 Electrical Systems" with the function switches or numeral input switches. q [F3]: Move to lower record q [F4]: Move to upper record q [F5]: Return to service menu screen q [F6]:
Confirm selection a You may enter a 2-digit code with the numeral input switches to select the record of that code and confirm it with [F6]. a The following figure shows the display of the air conditioner specification. If the heater specification is selected, "03 Heater Abnormality Record" is displayed. 4. Deleting "Abnormality Record" 1) While the "Electrical Systems" screen is displayed, perform the following operation with the numeral input switches. q Operation of switches (While pressing [4], perform the operation in order): [4] + [1] o [2] o [3] a Operate the switches similarly to the procedure for changing the ordinary display to the service mode. D155AX-6 25