Komatsu D155AX-6 — SPECIAL FUNCTIONS OF MACHINE MONITOR (EMMS)

SEN00681-01 30 Testing and adjusting a Entry order of items in table The items are entered in the order of their failure codes (incremental order). a Action code Attached: If the failure code is detected, the action code, failure code, and telephone No. (if regis- tered) are displayed on the ordinary screen to notify the operator of the fault. Not attached: Even if the failure code is detected, the machine monitor does not notify the operator of the fault. a Alarm buzzer q : When occurrence of an error is notified to the operator, the buzzer sounds (The operator can stop the buzzer with the alarm buzzer cancel switch). e :

Since the caution monitor is also turned ON, its function sounds the buzzer. a Component in charge MON: The machine monitor is in charge of detection of fault. ENG: The engine controller is in charge of detection of fault. P/T: The power train controller is in charge of detection of fault. W/E: Work equipment controller is in charge of detection of fault. a Category of record Mechanical equipment system: Fault information is recorded in the "Mechanical Systems". Electrical equipment system: Fault information is recorded in the "Electrical Systems" .

34 D155AX-6 Action code Failure code Trouble (Displayed on screen) Alarm buzzer Component in charge Category of history E03 DXJ9KB Blade right 2 EPC: Short circuit q W/E Electrical system E03 DXJ9KY Blade right 2 EPC: Short circuit q W/E Electrical system E01 DXJAKA Q-drop EPC: Disconnection W/E Electrical system E01 DXJAKB Q-drop EPC: Short circuit W/E Electrical system E01 DXJAKY Q-drop EPC: Short circuit W/E Electrical system E02 DXJBKA S/C ECMV: Disconnection q P/T Electrical system E02 DXJBKB S/C ECMV: Short circuit q P/T Electrical system E02 DXJBKY S/C ECMV: Short circuit q P/T Electrical system