SEN00681-01 30 Testing and adjusting Default setting (Setting of maintenance pass- word) Check or change various settings related to the machine monitor and machine by default setting. The function of setting maintenance password is used to set the display of the password screen when the functions related to the maintenance are used in the operator mode. q [F6]: Confirm selection and return to default screen 1. Selecting menu Select "06 Default" on the "Service Menu" screen. 4. Displaying maintenance password screen When the following operation is performed, the password screen is displayed in the operator mode.
q The ordinary screen is changed to the maintenance mode (with [F5]) and then the "Maintenance table" screen is changed to the "Maintenance interval reset" screen. 2. Selecting sub menu After the "Default" screen is displayed, select "03 Maintenance Password" with the function switches or numeral input switches. a Select this item similarly to an item on the Service menu screen. 5. Changing maintenance password The password can be changed by operating the switches specially in the operator mode. a See "Function of changing maintenance password" in the operator mode. a Default password:
[000000] a If the password setting is changed from "Enable" to "Disable", the password is reset to the default. a When "Enable" is set again, be sure to set a new password. a The maintenance password is different from the engine start lock password. 3. Selecting Enable/Disable After the "Maintenance Password" screen is displayed, select the setting with the function switches. q Disable: Password screen is not displayed q Enable: Password screen is displayed q [F3]: Move to lower item q [F4]: Move to upper item q [F5]: Cancel selection and return to Initial- ization screen 42 D155AX-6