Komatsu D155AX-6 — SPECIAL FUNCTIONS OF MACHINE MONITOR (EMMS)

30 Testing and adjusting SEN00681-01 Adjustment ID: 0002 (Power train controller initial- ization) Adjustment ID: 0004 (Work equipment specifica- tion setting) q This adjustment code is used to initialize the specification code recognized by the power train controller and the set values of the mem- ory in the controller. a After the power train controller is replaced, be sure to carry out this adjustment once. q This adjustment code is used to make the work equipment controller recognize the type of the work equipment. a After the work equipment controller is re- placed, be sure to carry out this adjustment once. q Functions of function switches [F3]: Unused [F4]: Unused [F5]:

Return to adjustment item selecting screen (ID inputting screen) [F6]: Save setting q Functions of function switches [F3]: Increase specification value [CODE] [F4]: Decrease specification value [CODE] [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Save setting q Operating method: 1) Press [F6] and check that the alarm buzzer sounds. 2) Check that the displayed specification code [CODE] has changed from [5x5] to [555]. a If specification code [555] is not displayed, the controller wiring harness or the con- troller unit may be defective. a Even if this adjustment code is turned off, the setting is effective. q Operating method:

1) Press [F3] or [F4] to select the specifica- tion value [CODE] of the work equipment concerned. 2) Press [F6] and check that the alarm buzz- er sounds. k If the specification of the work equip- ment is different from the setting in the controller, the work equipment may move unexpectedly or an error may be made. Accordingly, be sure to match the controller to the work equipment. a Even if this adjustment code is turned off, the setting is effective. D155AX-6 47 CODE Type of work equipment 0 D ual tiltdozer 1 S ingle tiltdozer 2 M echanical dozer