Komatsu D155AX-6 — SPECIAL FUNCTIONS OF MACHINE MONITOR (EMMS)

SEN00681-01 30 Testing and adjusting Adjustment ID: 8005 (Blade tilt lever leftmost posi- tion adjustment) Adjustment ID: 8006 (Ripper lift lever neutral posi- tion adjustment) q This adjustment code is used to make the work equipment controller recognize the leftmost position of the tilt potentiometer of the blade control lever. a After the work equipment controller or blade control lever is replaced, be sure to carry out this adjustment once. q This adjustment code is used to make the work equipment controller recognize the neutral position of the lift potentiometer of the ripper control lever.

a After the work equipment controller or ripper control lever is replaced, be sure to carry out this adjustment once. q Functions of function switches [F3]: Unused [F4]: Unused [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Save adjustment value q Functions of function switches [F3]: Unused [F4]: Unused [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Save adjustment value q Operating method 1) Operate the blade control lever to the left stroke end of the tilting direction and keep it in that position. 2) Press [F6] and check that the alarm buzzer sounds. a Even if the adjustment is carried out, the displayed value does not change.

a Even if this adjustment code is turned off, the adjustment is effective. a This adjustment code is used to make the controller recognize the leftmost position of the potentiometer. It is not used to adjust the sensitivity of the blade control lever (For adjustment of the sensitivity of the blade control lever in the tilting direc- tion, carry out adjustment codes 8024 and 8025 ). q Operating method 1) Check that the ripper control lever is in the neutral position of the lifting direction and keep it in that position. 2) Press [F6] and check that the alarm buzzer sounds. a Even if the adjustment is carried out, the displayed value does not change.

a Even if this adjustment code is turned off, the adjustment is effective. a This adjustment code is used to make the controller recognize the neutral position of the potentiometer. It is not used to adjust the sensitivity of the ripper control lever. 62 D155AX-6