Komatsu D155AX-6 — SPECIAL FUNCTIONS OF MACHINE MONITOR (EMMS)

30 Testing and adjusting SEN00681-01 Adjustment ID: 8007 (Ripper lift lever max. raising position adjustment) Adjustment ID: 8008 (Ripper lift lever max. lower- ing position adjustment) q This adjustment code is used to make the work equipment controller recognize the maximum raising position of the lift potentiometer of the ripper control lever. a After the work equipment controller or ripper control lever is replaced, be sure to carry out this adjustment once. q This adjustment code is used to make the work equipment controller recognize the maximum lowering position of the lift potentiometer of the ripper control lever.

a After the work equipment controller or ripper control lever is replaced, be sure to carry out this adjustment once. q Functions of function switches [F3]: Unused [F4]: Unused [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Save adjustment value q Functions of function switches [F3]: Unused [F4]: Unused [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Save adjustment value q Operating method 1) Operate the ripper control lever to the rais- ing stroke end of the lifting direction and keep it in that position. 2) Press [F6] and check that the alarm buzzer sounds.

a Even if the adjustment is carried out, the displayed value does not change. a Even if this adjustment code is turned off, the adjustment is effective. a This adjustment code is used to make the controller recognize the maximum raising position of the potentiometer. It is not used to adjust the sensitivity of the ripper control lever. q Operating method 1) Operate the ripper control lever to the low- ering stroke end of the lifting direction and keep it in that position. 2) Press [F6] and check that the alarm buzzer sounds. a Even if the adjustment is carried out, the displayed value does not change. a Even if this adjustment code is turned off, the adjustment is effective.

a This adjustment code is used to make the controller recognize the maximum lower- ing position of the potentiometer. It is not used to adjust the sensitivity of the ripper control lever. D155AX-6 63