Komatsu D155AX-6 — SPECIAL FUNCTIONS OF MACHINE MONITOR (EMMS)

30 Testing and adjusting SEN00681-01 Adjustment ID: 9996 (Sudden stop prevent valve operation mode) Adjustment ID: 9997 (High idle cut mode) q This adjustment code is used to stop the sud- den stop prevent solenoid valve and right and left brake ECMV to check the operation of the sudden stop prevent valve. a Use this adjustment code for testing, adjusting, or troubleshooting when necessary. q This adjustment code is used to limit the high idle speed. a Use this adjustment code for work when nec- essary. q Functions of function switches [F3]: Increase adjustment value [HIGH IDLE RPM SET MODE] [F4]: Decrease adjustment value [HIGH IDLE RPM SET MODE] [F5]:

Return to adjustment item selecting screen (ID inputting screen) [F6]: Save adjustment value q Functions of function switches [F3]: Unused [F4]: Unused [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Unused q Operating method When this adjustment code is displayed, its function is effective and the sudden stop pre- vent solenoid valve and right and left brake ECMV are kept stopped. a After this adjustment code is turned OFF, its function is ineffective. q Operating method 1) Increase or decrease the adjustment val- ue by pressing [F3] or [F4]. 2) Press [F6] and check that the alarm buzz- er sounds.

a When resetting the limitation of the high idle speed, set the adjustment value to the original high idle speed (2,050 rpm). a Even if this adjustment code is turned off, the adjustment is effective. D155AX-6 69