SEN00682-01 30 Testing and adjusting 3. Power train controller 1) Remove the inside lower cover of the left console. a This cover is installed on the opposite side of the work equipment controller. 2) Insert or connect troubleshooting T-adapt- ers in or to connectors STC1 , STC2 , and STC3 of power train controller (8). a Since the connectors are fixed with screws, loosen those screws before disconnecting. a When returning the connectors, tight- en the screws to the specified torque. 2) Insert or connect troubleshooting T-adapt- ers in or to connectors WEC1 , WEC2 , and WEC3 of work equipment controller (10).
a Since the connectors are fixed with screws, loosen those screws before disconnecting. a When returning the connectors, tight- en the screws to the specified torque. 3 Screw: 2.83 ± 0.28 Nm {0.288 ± 0.028 kgm} 3 Screw: 2.83 ± 0.28 Nm {0.288 ± 0.028 kgm} 4. Work equipment controller 1) Remove the inside lower cover (9) of the left console. a This cover is installed on the opposite side of the work equipment controller. 4 D155AX-6