40 Troubleshooting SEN00717-01 Failure code [CA272] PCV1 Open Error 1 Circuit diagram related to supply pump PCV1 D155AX-6 41 Action code Failure code Trouble PCV1 Open Error (Engine controller system) E03 CA272 Contents of • trouble There is disconnection in PCV1 circuit of supply pump. Action of • controller None in particular. Problem that appears on machine Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective supply pump 1 PCV1 (Internal disconnec- tion) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
PCV1 (male) Resistance Between (1) – (2) 2.3 – 5.3 z Between (1), (2) – chassis ground Min. 1 Mz Disconnection in wiring har- ness (Disconnection in wiring 2 or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) – PCV1 (female) (1) (4) Resis- tance Max. 1 z Wiring harness between EGC1 (female) – PCV1 (female) (2) (5) Resis- tance Max. 1 z Ground fault in wiring har- 3 ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
Wiring harness between EGC1 (female) – PCV1 (female) (1) and chassis ground (4) Resis- M tance in. 1 Mz Wiring harness between EGC1 (female) – PCV1 (female) (2) and chassis ground (5) Resis- M tance in. 1 Mz 4 Defective engine controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. EGC1 (female) Resistance Between (4) – (5) 2.3 – 5.3 z Between (4), (5) – chassis ground Min. 1 Mz