Komatsu D155AX-6 — FAILURE CODE [CA273] PCV2 SHORT ERROR

SEN00717-01 40 Troubleshooting Failure code [CA273] PCV2 Short Error 1 Circuit diagram related to supply pump PCV2 42 D155AX-6 Action code Failure code Trouble PCV2 Short Error (Engine controller system) E03 CA273 Contents of • trouble There is short circuit in PCV2 circuit of supply pump. Action of • controller None in particular. Problem that appears on machine Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective supply pump 1 PCV2 (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

PCV2 (male) Resistance Between (1) – (2) 2.3 – 5.3 z Between (1), (2) – chassis ground Min. 1 Mz Ground fault in wiring har- 2 ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) – PCV2 (female) (1) and chassis ground (9) Resis- M tance in. 1 Mz Wiring harness between EGC1 (female) ( – PCV2 (female) (2) and chassis ground 10) Resis- M tance in. 1 Mz Hot short (Short circuit with 3 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.

Wiring harness between EGC1 (female) – PCV2 (female) (1) and chassis ground (9) Voltage Max. 1 V Wiring harness between EGC1 (female) ( – PCV2 (female) (2) and chassis ground 10) Voltage Max. 1 V 4 Defective engine controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. EGC1 (female) Resistance Between (9) – (10) 2.3 – 5.3 z Between (9), (10) – chassis ground Min. 1 Mz