40 Troubleshooting SEN00717-01 Failure code [CA325] Inj #6 (L#6) Open/Short Error 1 Circuit diagram related to injector #6 D155AX-6 47 Action code Failure code Trouble Inj #6 (L#6) Open/Short Error (Engine controller system) E03 CA325 Contents of trouble • There is disconnection or short circuit in injector #6 circuit. Action of controller • None in particular. Problem that appears on machine • Output drops. • Rotation is unstable.
Related information Possible cause and standard value in norma state Cause Defective injector #6 (Inter- 1 nal trouble) Disconnection in wiring har- ness (Disconnection in wiring 2 or defective contact in con- s nector) l Ground fault in wiring har- 3 ness (Contact with GND cir- cuit) 4 Defective engine controller Standard value in normal state/Remarks on troubleshooting efective injector #6 (Inter- al trouble) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. CN6 (male) Resistance Between (1) – (2) 0.4 – 1.1 z Between (1), (2) – chassis ground Min.
1 Mz isconnection in wiring har- ess (Disconnection in wiring r defective contact in con- ector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (57) – CN6 (female) (1) Resis- tance Max. 1 z Wiring harness between EGC1 (female) (59) – CN6 (female) (2) Resis- tance Max. 1 z round fault in wiring har- ess (Contact with GND cir- uit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (57) – CN6 (female) (1) and chassis ground Resis- tance Min.
1 Mz Wiring harness between EGC1 (female) (59) – CN6 (female) (2) and chassis ground Resis- tance Min. 1 Mz efective engine controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. EGC1 (female) Resistance Between (57) – (59) 0.4 – 1.1 z Between (57), (59) – chassis ground Min. 1 Mz