Komatsu D155AX-6 — FAILURE CODE [CA324] INJ #3 (L#3) OPEN/SHORT ERROR

SEN00717-01 40 Troubleshooting Failure code [CA324] Inj #3 (L#3) Open/Short Error 1 Circuit diagram related to injector #3 46 D155AX-6 Action code Failure code Trouble Inj #3 (L#3) Open/Short Error (Engine controller system) E03 CA324 Contents of trouble • There is disconnection or short circuit in injector #3 circuit. Action of controller • None in particular. Problem that appears on machine • Output drops. • Rotation is unstable.

Related information Possible cause and standard value in norm state Cause Defective injector #3 (Inter- 1 nal trouble) Disconnection in wiring har- ness (Disconnection in wiring 2 or defective contact in con- s nector) al Ground fault in wiring har- 3 ness (Contact with GND cir- cuit) 4 Defective engine controller Standard value in normal state/Remarks on troubleshooting efective injector #3 (Inter- al trouble) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. CN3 (male) Resistance Between (1) – (2) 0.4 – 1.1 z Between (1), (2) – chassis ground Min.

1 Mz isconnection in wiring har- ess (Disconnection in wiring r defective contact in con- ector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (55) – CN3 (female) (1) Resis- tance Max. 1 z Wiring harness between EGC1 (female) (52) – CN3 (female) (2) Resis- tance Max. 1 z round fault in wiring har- ess (Contact with GND cir- uit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (55) – CN3 (female) (1) and chassis ground Resis- tance Min.

1 Mz Wiring harness between EGC1 (female) (52) – CN3 (female) (2) and chassis ground Resis- tance Min. 1 Mz efective engine controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. EGC1 (female) Resistance Between (55) – (52) 0.4 – 1.1 z Between (55), (52) – chassis ground Min. 1 Mz