SEN00717-01 40 Troubleshooting Failure code [CA559] Rail Press Low Error 1 Carry out the above troubleshooting and take a record of the contents of the attached "Check sheet for rail pressure low error". 64 D155AX-6 Action code Failure code Trouble Rail Press Low Error (Engine controller system) E02 CA559 Contents of trouble • Supply pump does not feed fuel (level 1). Action of controller • Limits common rail pressure. Problem that appears on machine • Engine output drops. Related information • Common rail pressure can be checked with monitoring function. (Code:
36400 Rail Pressure) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective related system If another failure code is indicated, carry out troubleshooting for it. 2 Use of improper fuel Check fuel used directly for improper quality. 3 Defective low-pressure cir- cuit device a For contents of troubleshooting, see Note 1. For check of pres- sure in fuel low-pressure circuit, see Testing and adjusting, Testing fuel pressure. Pressure in fuel low-pressure circuit (high idle) Min. 0.15 MPa {Min. 1.5 kg/cm2} 4 Clogging of filter/strainer a For contents of troubleshooting, see Note 2.
5 Defective electrical system of supply pump PCV Supply pump PCV may have electric trouble. Carry out trouble- shooting for following codes; [CA271], [CA272], [CA273], [CA274]. 6 Defective common rail pres- sure sensor Common rail pressure sensor may be defective. Check wiring har- ness for damage. 7 Defective pressure limiter a For testing of leakage from pressure limiter, see Testing and adjusting, Measuring fuel return rate and fuel leakage. Leakage from pressure limiter (Operation equivalent to rated operation (under stall load)) Max.
10 cc/min 8 Defective injector a For measuring of return (spill) limit from injector, see Testing and adjusting, Measuring fuel return rate and fuel leakage. Speed in rated operation (stall load) Return (Spill) limit from injector 1,600 rpm 960 cc/min 1,700 rpm 1,020 cc/min 1,800 rpm 1,080 cc/min 1,900 rpm 1,140 cc/min 2,000 rpm 1,200 cc/min 9 Defective supply pump If causes 1 – 8 are not detected, supply pump may be defective.