Komatsu D155AX-6 — FAILURE CODE [DB90KR] PT CONTROLLER: CAN COMMUNICATION LOST

SEN00718-01 40 Troubleshooting Failure code [DB90KR] PT controller: Can communication lost 1 62 D155AX-6 Action code Failure code Trouble PT controller: Can communication lost (Power train controller system) E03 DB90KR Contents of trouble • Power train controller cannot recognize machine monitor, engine controller or work equipment con- troller in CAN communication circuit. Action of controller • Limits operation of engine and transmission. Problem that appears on machine • System may not operate normally. • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. Related information • Method of reproducing failure code:

Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between CM02 (female) (8), (9) – EGC2 (female) (46), STC2 (female) (32) or WEC2 (female) (32) Resis- tance Max. 1 z Wiring harness between CM02 (female) (10) – EGC2 (female) (47), STC2 (female) (22) or WEC2 (female) (22) Resis- tance Max.

1 z 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between CM02 (female) (8), (9) – EGC2 (female) (46), STC2 (female) (32), WEC2 (female) (32), ACCN (female) (17), SRV (male) (3) or CA1 (female) (A) and chassis ground Resis- tance Min. 1 Mz Wiring harness between CM02 (female) (10) – EGC2 (female) (47), STC2 (female) (22), WEC2 (female) (22), ACCN (female) (18), SRV (male) (10) or CA1 (female) (B) and chassis ground Resis- tance Min.

1 Mz 3 Hot short (Contact with GND circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between CM02 (female) (8), (9) – EGC2 (female) (46), STC2 (female) (32), WEC2 (female) (32), ACCN (female) (17), SRV (male) (3) or CA1 (female) (A) and chassis ground Voltage Max. 1 V Wiring harness between CM02 (female) (10) – EGC2 (female) (47), STC2 (female) (22), WEC2 (female) (22), ACCN (female) (18), SRV (male) (10) or CA1 (female) (B) and chassis ground Voltage Max.

1 V 4 Defective CAN terminal resistance (Internal discon- nection or short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. CA1 (male) Resistance Between (A) – (B) Approx. 120 z 5 Defective machine monitor or controller If causes 1 – 4 are not detected, machine monitor, engine control- ler, power train controller or work equipment controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)