Komatsu D155AX-6 — FAILURE CODE [DB90KK] WE CONTROLLER: SOURCE VOLTAGE REDUCTION

40 Troubleshooting SEN00718-01 Circuit diagram related to work equipment controller power supply D155AX-6 61 Possible cause and standard value in norm state Cause s Defective work equipment al 4 controller Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 Starting switch Voltage Between (1), (11) – (21), (31), (32), (33) OFF 20 – 30 V Between (2), (12), (22) – (21), (31), (32), (33) ON 20 – 30 V